Monitoring stats like carbon dioxide, temperature, and humidity are imperative to growing healthy, strong plants with a hydroponics system. Help keep those levels in check with the Autopilot Desktop CO2 Monitor and Data Logger.
This monitor features a digital memory chart that shows and records stats over an adjustable 24 hour or 7 day period. It has an audible alarm for low or high CO2 levels and a light that indicates if it’s on target. View the charts from a weekly, daily, hourly, or per minute view.
- Monitors carbon dioxide, relative humidity, and temperature of your grow room or greenhouse on a clear LED screen
- Digital memory chart shows and records stats over an adjustable 24-hour or 7-day period
- 2-channel low drift NDIR gas sensor and audible alarm for low or high CO2 levels
- Green power supply is compatible with a standard smartphone charger
- Trend Chart: Shows variable Min/Hr/Day/Wk for readings of CO2/RH/Temperature
- Comes with 2 micro USB cables for power and USB AC adapter
- Operating temperature: 32 to 122 degrees F
- Hook-and-loop fastener along the back that attaches to an external battery pack (battery pack not included)
- Multiple hanging options
- Operating and storage relative humidity (RH): 0-95%, noncondensing
- Carbon-dioxide measurement: Accuracy at 0-3000 parts per million, +/- 50 ppm or +/- 5%, whichever is greater; accuracy over 3000 ppm, +/- 7%; repeatability, 20 ppm at 400 ppm (standard deviation of 10 readings in 1 minute); measurement range, 0-5000 ppm; display resolution, 1 ppm (1-1000), 5 ppm (1000-2000), 10 ppm (>2000); temp dependence, +/-0.1% of reading per degree Celsius or +/-2 ppm per degree Celsius, whichever is greater, referenced to 25 degrees C; pressure dependence, 0.13% of reading per mm Hg (corrected by user??s altitude input); response time, < 2 minutes for 63% of step change or <4.6 minutes for 90% step change; warm-up time, < 30 seconds
- Temperature measurement: Operating temp, 32 to 122 degrees F (0-50 C); display resolution, 0.1 degree F (0.1 degree C); accuracy, +/- 1 degree F (+/- 0.5 degree C); response time, < 20 minutes (63%)
- RH measurement: Range, 10-20%; accuracy, +/- 5%; resolution, 1% on main reading, 0.1% on max min reading
- Voltage: 120 volts
- Dimensions (L x W x D): 4.7 x 3.6 x 1.1 inches
- Weight: 1 pound
- Warranty: 60-day warranty
- Quantity: 2
Reviews
There are no reviews yet.